Quick Search

PRODUCTS

PREVENTOL ON-S


Preventol ON-S is an in-can preservative and product protection biocide used to control bacteria, fungi, and yeast in water-based industrial formulations.
Preventol ON-S helps prevent spoilage effects such as odor formation, viscosity loss, gas formation, discoloration, and microbial slime, supporting longer shelf life and consistent product quality.
Preventol ON-S is typically supplied as a liquid biocide preparation for easy incorporation into coatings, dispersions, adhesives, and related waterborne products, but Preventol ON-S must be used according to local biocide regulations and handled with appropriate safety measures due to irritation and sensitization potential.

CAS Number: Mixture (supplier-specific)
EC Number: Mixture (supplier-specific)
Molecular Formula: Variable (biocidal mixture)
Molecular Weight: Variable (mixture)

Synonyms: Preventol ON-S, Preventol® ON-S, In-can Preservative ON-S, Industrial Preservative ON-S, Waterborne Biocide ON-S, Product Protection Biocide ON-S, Paint Preservative ON-S, Adhesive Preservative ON-S, Latex Preservative ON-S, Broad-Spectrum Preservative, Microbial Control Additive, In-Process Biocide, Preventol ON-S, PREVENTOL ON-S, Preventol® ON-S, PREVENTOL® ON-S, Preventol ONS, PREVENTOL ONS, Preventol ON S, PREVENTOL ON S, Preventol ON-S (trade name), Preventol ON-S biocide, Preventol ON-S preservative, Preventol ON-S microbicide, Preventol ON-S antimicrobial, Preventol ON-S in-can preservative, Preventol ON-S product protection, Preventol ON-S material preservative, Preventol ON-S industrial preservative, Preventol ON-S coating preservative, Preventol ON-S paint preservative, Preventol ON-S emulsion preservative, Preventol ON-S latex preservative, Preventol ON-S polymer dispersion preservative, Preventol ON-S waterborne preservative, Preventol ON-S water-based preservative, Preventol ON-S aqueous system preservative, Preventol ON-S additive, Preventol ON-S preservation agent, Preventol ON-S bactericide (use context), Preventol ON-S fungicide (use context), Preventol ON-S anti-bacterial (use context), Preventol ON-S anti-fungal (use context), Preventol ON-S slime control (use context), Preventol ON-S microbial control agent, Preventol ON-S can preservative, Preventol ON-S storage preservative, Preventol ON-S formulation preservative, Preventol ON-S formulation additive, Preventol ON-S biocidal additive, Preventol ON-S antimicrobial additive, Preventol ON-S in-can biocidal additive, Preventol ON-S for paints, Preventol ON-S for coatings, Preventol ON-S for varnishes, Preventol ON-S for printing inks (use context), Preventol ON-S for pigment pastes (use context), Preventol ON-S for fillers slurries (use context), Preventol ON-S for adhesives, Preventol ON-S for sealants, Preventol ON-S for construction chemicals, Preventol ON-S for polymer emulsions, Preventol ON-S for aqueous cleaners (use context), Preventol ON-S for detergents (use context), Preventol ON-S for household products (use context), Preventol ON-S for industrial water-based products, Preventol ON-S broad-spectrum preservative (use context), Preventol ON-S broad spectrum biocide (use context)

APPLICATIONS


Preventol ON-S is used in water-based paints and decorative coatings to prevent in-can microbial spoilage during storage and transport.
Preventol ON-S is incorporated into primers and undercoats to reduce odor formation and viscosity loss caused by microbial contamination.
Preventol ON-S is used in low-VOC paint formulations where water activity is high and spoilage risk can increase.

Preventol ON-S is used in pigment slurries, millbases, and tinting pastes to control microbial growth during production and storage.
Preventol ON-S is incorporated into universal colorants to improve shelf stability and maintain stable dispensing viscosity.
Preventol ON-S is used in coating colorant concentrates to reduce spoilage-related shade drift and container odor.

Preventol ON-S is used in polymer dispersions and latex emulsions to protect binders from microbial growth and degradation.
Preventol ON-S is incorporated into acrylic, styrene-acrylic, and vinyl dispersions to reduce bacterial contamination in tanks, totes, and packaged goods.
Preventol ON-S is used in emulsion intermediates to prevent microbial slime that can interfere with filtration and QC tests.

Preventol ON-S is used in water-based adhesives to maintain stable viscosity, tack, and application properties during shelf life.
Preventol ON-S is incorporated into paper, packaging, and woodworking adhesives to prevent odor and gas formation after storage.
Preventol ON-S is used in dispersion-based pressure-sensitive adhesives to reduce spoilage risk after repeated opening.

Preventol ON-S is used in construction chemicals such as ready-to-use fillers, putties, and joint compounds to prevent microbial contamination and odor.
Preventol ON-S is incorporated into tile adhesives and wet mortars to improve shelf life and reduce spoilage-related failures.
Preventol ON-S is used in acrylic sealants and water-based caulks to prevent microbial growth during storage.

Preventol ON-S is used in water-based printing inks and varnishes to prevent microbial spoilage and maintain print consistency.
Preventol ON-S is incorporated into overprint coatings to reduce bacterial growth and odor development in stored batches.
Preventol ON-S is used in ink concentrates to improve stability during pumping and recirculation.

Preventol ON-S is used in household and institutional cleaning products where preservation is needed in water-rich formulations.
Preventol ON-S is incorporated into detergents and specialty cleaners to reduce microbial degradation and maintain product appearance.
Preventol ON-S is used in liquid concentrates where contamination risk increases after repeated consumer opening.

Preventol ON-S is used in textile and leather auxiliaries to protect water-based process chemicals from bacterial and fungal growth.
Preventol ON-S is incorporated into finishing agents and coating dispersions to prevent spoilage during storage and transport.
Preventol ON-S is used in water-based sizing and binder systems to reduce microbial contamination in tanks and lines.

Preventol ON-S is used in laboratory and pilot production to stabilize waterborne formulations during development and stability testing.
Preventol ON-S is incorporated into retained samples to prevent microbial changes that can interfere with QC evaluations.
Preventol ON-S is valued because Preventol ON-S helps maintain product quality, extends shelf life, and reduces spoilage-related complaints in many water-based industrial products.

DESCRIPTION


Preventol ON-S is an in-can preservative intended to protect formulated products, and Preventol ON-S works by inhibiting microbial growth in aqueous media.
Preventol ON-S is typically dosed at low levels, and the effective use level depends on pH, temperature, raw material contamination, and the intended shelf life target.
Preventol ON-S should be added with adequate mixing to ensure uniform distribution, and Preventol ON-S is often added during the final stage to reduce exposure to harsh processing conditions that can reduce biocide activity.

Preventol ON-S performance can be influenced by formulation components such as surfactants, thickeners, pigments, and reducing agents, so compatibility screening is recommended.
Preventol ON-S may be less effective in strongly alkaline or strongly reducing environments, so the preservation strategy should be optimized for challenging systems.
Preventol ON-S is designed for product preservation, and Preventol ON-S should not be confused with dry-film preservatives that protect cured coatings from surface mold.

Preventol ON-S can cause skin sensitization in susceptible individuals, so Preventol ON-S should be handled with appropriate PPE and exposure controls.
Preventol ON-S should be stored in original tightly closed packaging and protected from extreme temperatures to maintain stability.
Preventol ON-S must be used in compliance with local biocide regulations and labeling requirements for the target market and product category.

PROPERTIES


Common Name: Preventol ON-S
Function: In-can preservative / product protection biocide for water-based systems
Chemical Type: Biocidal mixture (supplier-specific)
Appearance: Clear to slightly hazy liquid (typical; grade dependent)
Odor: Mild characteristic odor (typical)
Solubility: Miscible or readily dispersible in water (typical)
pH (as supplied): Grade dependent
Active Content: Grade dependent (supplier-specific)
Effective Spectrum: Broad activity against bacteria, fungi, and yeast (formulation dependent)
Compatibility: Designed for many waterborne coatings, dispersions, adhesives, and cleaners (system dependent)
Stability: Stable under recommended storage; avoid extreme heat and conditions that can deactivate biocides
Regulatory Status: Biocide regulations and approvals are market dependent and must be verified for intended use
Storage Temperature: Typically 5–30°C, protect from frost and excessive heat
Shelf Life: Typically 12–24 months in original sealed packaging (supplier dependent)

FIRST AID


Inhalation:
Move to fresh air if vapors or mists are inhaled.
Seek medical attention if respiratory symptoms persist.
Avoid breathing aerosols during high-shear mixing and spraying operations.

Skin Contact:
Remove contaminated clothing and wash skin thoroughly with soap and water.
Seek medical attention if irritation, rash, or sensitization symptoms develop.
Do not reuse contaminated clothing until it has been washed.

Eye Contact:
Rinse cautiously with water for several minutes.
Remove contact lenses if present and easy to do, then continue rinsing.
Seek medical attention if irritation persists.

Ingestion:
Rinse mouth with water and do not induce vomiting.
Seek medical attention promptly if a significant amount is swallowed.
Never give anything by mouth to an unconscious person.

Note to Physicians:
Treat symptomatically.
Skin sensitization potential should be considered if dermatitis develops.
Provide supportive care based on exposure route and symptoms.

HANDLING AND STORAGE


Handling:
Use appropriate PPE including chemical-resistant gloves and safety glasses or goggles.
Avoid skin contact and avoid generating mists, and wash hands after handling.
Do not eat, drink, or smoke in handling areas, and maintain good industrial hygiene practices.

Ventilation:
Use general ventilation for normal handling.
Use local exhaust where aerosols or mists can be generated during mixing, pumping, or spraying.
Avoid confined areas where vapors or mists may accumulate.

Storage:
Store in tightly closed original containers in a cool, dry, well-ventilated place.
Protect from freezing and from excessive heat, and keep away from direct sunlight.
Keep away from incompatible chemicals that may deactivate biocides or cause decomposition (system dependent).

Spill and Leak Procedures:
Contain the spill and absorb with inert material.
Collect into suitable containers for disposal according to local regulations.
Wash the contaminated area with water while preventing slip hazards on wet surfaces.

Handling Precautions:
Confirm the effective dose in the finished formulation using microbial challenge testing where appropriate.
Verify compatibility with pH, thickeners, pigments, and reducing agents to avoid loss of preservative efficacy.
Rotate stock using FIFO practices to maintain consistent quality and predictable preservation performance.

  • Share !