Quick Search

PRODUCTS

GENIOSIL GF 80

DESCRIPTION:
GENIOSIL GF 80 is an epoxy functional alkoxysilane. 
GENIOSIL GF 80 is a clear, colorless liquid with a characteristic odor. 

CAS No.: 2530-83-8

The use of GENIOSIL® GF 80 as a coupling agent in mineral-filled plastics improves filler dispersibility, reduces its sedimentation tendency and greatly lowers the resin's viscosity. 
GENIOSIL GF 80 can be applied in adhesives, emulsion paint, coatings and filler treatment.


USES OF GENIOSIL GF 80:
The use of GENIOSIL® GF 80 US as a coupling agent in mineral-filled plastics improves filler dispersibility, reduces its sedimentation tendency and greatly lowers the resin's viscosity. 

In addition, it leads to higher filler
loading and a marked increase in water (vapor) resistance, as well as resistance to acids and bases. 

As a component of adhesives and sealants, GENIOSIL® GF 80 US improves both adhesion to the substrate and mechanical properties such as flexural strength, tensile strength and modulus of elasticity.

Application details:
GENIOSIL® GF 80 US is mainly used in the treatment of inorganic fillers (e.g. glass, mineral and glass wools, ATH, kaolin, mica, metallic oxides) for various polymer types, such as epoxy resins, urethane, melamine resins, EPDM, and for polysulfides, and an additive or primer in coatings, paints, adhesives and sealants.


GENIOSIL® GF 80 by Wacker is an organofunctional 3 is Glycidoxypropyltrimethoxysilane. 
GENIOSIL GF 80 is Used as an adhesion promoter in construction, joints and sanitary sealants. 

GENIOSIL GF 80 is also recommended for construction adhesives, consumer/ DIY, wood and flooring adhesives. 
GENIOSIL® GF 80 improves mechanical properties such as tensile strength and modulus of elasticity.

GENIOSIL® GF 80 acts as a coupling agent in mineral-filled plastics improves filler dispersibility, reduces its sedimentation tendency and greatly lowers the resin's viscosity. 


GENIOSIL GF 80 leads to higher filler loading and a marked increase in water (vapor) resistance, as well as resistance to acids and bases. 
As a component of adhesives and sealants, GENIOSIL® GF 80 improves both adhesion to the substrate and mechanical properties such as flexural strength, tensile strength and modulus of elasticity. 
GENIOSIL® GF 80 can work as a bridge between inorganic and organic substrates.


PROCESSING:
GENIOSIL® GF 80 US is highly miscible with standard organic solvents, such as alcohols, hydrocarbons and
acetone. 

GENIOSIL® GF 80 US  can be physically dissolved in neutral water to an extent upward of 5 wt %. 
Much stronger homogeneous aqueous concentrations (up to 50% by weight) can be obtained by way of hydrolysis. 

By incorporating a hydrolysis catalyst (e.g acetic acid), hydrolysis can be greatly accelerated at pH values of 3 to 4. 
However, at pH values below 4, the epoxy ring may start to open.


TECHNICAL DESCRIPTION OF GENIOSIL GF 80
Trade Grade:
GENIOSIL GF 80
Trade Name:
GENIOSIL
Principal:
Wacker
CAS Number:
-
Group:
modifiers
Sub Group:
Compatibilizers Coupling Agents
Product Type:
Silanes
Chemical/Common Name:
3-Glycidoxypropyltrimethoxysilane
Product number:
131997
Unit of Measure:
KG

SAFETY INFORMATION ABOUT GENIOSIL GF 80
 
 
First aid measures:
Description of first aid measures:
General advice:
Consult a physician. 
Show this safety data sheet to the doctor in attendance.
Move out of dangerous area:
 
If inhaled:
If breathed in, move person into fresh air. 
If not breathing, give artificial respiration.
Consult a physician.
In case of skin contact:
Take off contaminated clothing and shoes immediately. 
Wash off with soap and plenty of water.
Consult a physician.
 
In case of eye contact:
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
Continue rinsing eyes during transport to hospital.
 
If swallowed:
Do NOT induce vomiting. 
Never give anything by mouth to an unconscious person. 
Rinse mouth with water. 
Consult a physician.
 
Firefighting measures:
Extinguishing media:
Suitable extinguishing media:
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture
Carbon oxides, Nitrogen oxides (NOx), Hydrogen chloride gas
 
Advice for firefighters:
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental release measures:
Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. 
 
Avoid breathing vapours, mist or gas. 
Evacuate personnel to safe areas.
 
Environmental precautions:
Prevent further leakage or spillage if safe to do so.
Do not let product enter drains.
Discharge into the environment must be avoided.
 
Methods and materials for containment and cleaning up:
Soak up with inert absorbent material and dispose of as hazardous waste. 
Keep in suitable, closed containers for disposal.
 
Handling and storage:
Precautions for safe handling:
Avoid inhalation of vapour or mist.
 
Conditions for safe storage, including any incompatibilities:
Keep container tightly closed in a dry and well-ventilated place. 
Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Storage class (TRGS 510): 8A: Combustible, corrosive hazardous materials
 
Exposure controls/personal protection:
Control parameters:
Components with workplace control parameters
Contains no substances with occupational exposure limit values.
Exposure controls:
Appropriate engineering controls:
Handle in accordance with good industrial hygiene and safety practice.
Wash hands before breaks and at the end of workday.
 
Personal protective equipment:
Eye/face protection:
Tightly fitting safety goggles. 
Faceshield (8-inch minimum). 
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
 
Skin protection:
Handle with gloves. 
Gloves must be inspected prior to use. 
Use proper glove
removal technique (without touching glove's outer surface) to avoid skin contact with this product. 
Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. 
Wash and dry hands.
 
Full contact:
Material: Nitrile rubber
Minimum layer thickness: 0.11 mm
Break through time: 480 min
Material tested:Dermatril (KCL 740 / Aldrich Z677272, Size M)
Splash contact
Material: Nitrile rubber
Minimum layer thickness: 0.11 mm
Break through time: 480 min
Material tested:Dermatril (KCL 740 / Aldrich Z677272, Size M)
It should not be construed as offering an approval for any specific use scenario.
 
Body Protection:
Complete suit protecting against chemicals, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection:
Where risk assessment shows air-purifying respirators are appropriate use a fullface respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. 
 
If the respirator is the sole means of protection, use a full-face supplied air respirator. 
Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Control of environmental exposure
Prevent further leakage or spillage if safe to do so. 
Do not let product enter drains.
Discharge into the environment must be avoided.
 
Stability and reactivity:
Chemical stability:
Stable under recommended storage conditions.
Incompatible materials:
Strong oxidizing agents:
Hazardous decomposition products:
Hazardous decomposition products formed under fire conditions. 
Carbon oxides, Nitrogen oxides (NOx), Hydrogen chloride gas.
 
Disposal considerations:
Waste treatment methods:
Product:
Offer surplus and non-recyclable solutions to a licensed disposal company. 
Contact a licensed professional waste disposal service to dispose of this material.
Contaminated packaging:
Dispose of as unused product.
 

  • Share !
E-NEWSLETTER